Displaying Optical Module Information
To determine whether optical modules delivered for Huawei switches before January 1, 2016 are certified ones, contact Huawei
How Do I Check the Transmit and Receive Optical Power of an
Run the display interface transceiver verbose command to check the transmit and receive optical power of an optical module. In the
Checking TX / RX optical power for Huawei Switches and Routers
Here is an example on how to query or display optical power of an interface in a Huawei Router. This is tested using NetEngine40E
Checking the Optical Module Type
Check whether the optical module used on the switch is certified by Huawei switches. For the Huawei-certified optical modules,
Checking the Receive and Transmit Optical Power
Run the display interface interface-type interface-number transceiver verbose command to check whether the receive optical power
Troubleshooting Interface Down Problems
Check whether the receive optical power and transmit optical power are normal. Run the display interface interface-type interface
Typical Troubleshooting Cases of Optical Module
Use an optical power meter to measure the receive power of the port. Form a loop on the port using an optical fiber, and check
Checking the Optical Module Type
The selected optical modules must be supported by the optical interfaces. Check whether the optical module used on the switch is
Checking the Receive and Transmit Optical Power
Check whether the distance between the two devices exceeds the maximum transmission distance of the remote optical module. If
Checking the Optical Module
Change the optical module or fiber of the peer and test the receive optical power again. Check whether the transmission distance
Introduction of Optical Modules on Huawei Switches
Check Optical Module Parameters: If an optical module is installed in a running switch, you can run the display transceiver command
Checking Whether the Rx and Tx Optical Power of the Interfaces at
If only the number of B3 bit errors increases, check whether the link directly connecting the remote router and SDH transmission
Checking the Interface Status and Configuration Parameters
If a message is displayed, indicating that the optical module is not in position, remove and then properly insert the optical module. If
Checking that the Optical Power Is Within the Normal Range
In the preceding command output, the information in bold shows the optical power of the optical module. If the value of Rx Optical
Related Video Reference
This video was associated with the source search result. Verify technical details against current product documentation and project requirements.
This reference is intended for preliminary optical-network research. Compatibility, link budgets, installation methods, test limits and applicable standards must be verified for the specific project.